CONCOURSE VILLAGE, INC
Data Freshness & Provenance
Inspection coverage
15 inspections on record
Active providers
License status: Registration
Last refreshed
April 6, 2026
Latest inspection
January 15, 2026
Provenance
New York licensing inspections and DaycareCheck scoring
Quick Facts
These facts are normalized from the official record so they can be quoted directly.
Updated April 6, 2026
- Provider
- CONCOURSE VILLAGE, INC
- License number
- 654596
- Location
- 777 Concourse Village East, Bronx, NY 10451
- Status
- Registration
- Safety grade
- F (Poor), score 55.0/100
- Inspection record
- 15 inspections, last inspected January 15, 2026
- Provenance
- Official state licensing inspections and DaycareCheck scoring. Last refreshed April 6, 2026.
Safety Scorecard
50
Total Violations
Jan 15, 2026
Last Inspection
35
Capacity
Violation Timeline
Violations by month over the last 3 years, colored by severity.
All Violations (50)
Applicants for renewal of a registration must submit to the Office at least 60 days in advance of the expiration date of the registration the following: documentation from service personnel licensed by the New York State Department of State to perform fire alarm systems maintenance, repair and testing which shows that fire alarm and detection systems have been inspected, tested and maintained during the current registration period in accordance with the applicable requirements of the Fire and Building Code of New York State;
Resolution: Not Corrected
Applicants for renewal of a registration may not be issued a registration until an inspection of the program has been conducted showing compliance with the requirements of this Part and the relevant provisions of the Social Services Law.
Resolution: Not Corrected
All such inspections, testing and maintenance must be conducted by service personnel licensed by the New York State Department of State to perform fire alarm systems maintenance, repair and testing.
Resolution: Not Corrected
All such inspections, testing and maintenance must be conducted by service personnel licensed by the New York State Department of State to perform fire alarm systems maintenance, repair and testing.
Resolution: Not Corrected
Applicants for renewal of a registration must submit to the Office at least 60 days in advance of the expiration date of the registration the following: documentation from service personnel licensed by the New York State Department of State to perform fire alarm systems maintenance, repair and testing which shows that fire alarm and detection systems have been inspected, tested and maintained during the current registration period in accordance with the applicable requirements of the Fire and Building Code of New York State;
Resolution: Not Corrected
All such inspections, testing and maintenance must be conducted by service personnel licensed by the New York State Department of State to perform fire alarm systems maintenance, repair and testing.
Resolution: Not Corrected
Applicants for renewal of a registration may not be issued a registration until an inspection of the program has been conducted showing compliance with the requirements of this Part and the relevant provisions of the Social Services Law.
Resolution: Not Corrected
Applicants for renewal of a registration must submit to the Office at least 60 days in advance of the expiration date of the registration the following: documentation from service personnel licensed by the New York State Department of State to perform fire alarm systems maintenance, repair and testing which shows that fire alarm and detection systems have been inspected, tested and maintained during the current registration period in accordance with the applicable requirements of the Fire and Building Code of New York State;
Resolution: Not Corrected
All such inspections, testing and maintenance must be conducted by service personnel licensed by the New York State Department of State to perform fire alarm systems maintenance, repair and testing.
Resolution: Not Corrected
Applicants for renewal of a registration may not be issued a registration until an inspection of the program has been conducted showing compliance with the requirements of this Part and the relevant provisions of the Social Services Law.
Resolution: Not Corrected
Applicants for renewal of a registration must submit to the Office at least 60 days in advance of the expiration date of the registration the following: documentation from service personnel licensed by the New York State Department of State to perform fire alarm systems maintenance, repair and testing which shows that fire alarm and detection systems have been inspected, tested and maintained during the current registration period in accordance with the applicable requirements of the Fire and Building Code of New York State;
Resolution: Not Corrected
Applicants for renewal of a registration may not be issued a registration until an inspection of the program has been conducted showing compliance with the requirements of this Part and the relevant provisions of the Social Services Law.
Resolution: Not Corrected
All such inspections, testing and maintenance must be conducted by service personnel licensed by the New York State Department of State to perform fire alarm systems maintenance, repair and testing.
Resolution: Not Corrected
Applicants for renewal of a registration must submit to the Office at least 60 days in advance of the expiration date of the registration the following: documentation from service personnel licensed by the New York State Department of State to perform fire alarm systems maintenance, repair and testing which shows that fire alarm and detection systems have been inspected, tested and maintained during the current registration period in accordance with the applicable requirements of the Fire and Building Code of New York State;
Resolution: Not Corrected
Applicants for renewal of a registration may not be issued a registration until an inspection of the program has been conducted showing compliance with the requirements of this Part and the relevant provisions of the Social Services Law.
Resolution: Not Corrected
Applicants for a registration must submit to the Office: certificate of occupancy or other documentation from the local government authority having jurisdiction for determining compliance with the Fire Code and Building Code of New York State, or other applicable fire and building codes when the Fire and Building Code of New York State is not applicable, showing that the facility has been inspected and approved within the 12 months preceding the date of application for use as a child school age child care program, in accordance with the appropriate provisions of such code;
Resolution: Not Corrected
Applicants for a registration must submit to the Office: certificate of occupancy or other documentation from the local government authority having jurisdiction for determining compliance with the Fire Code and Building Code of New York State, or other applicable fire and building codes when the Fire and Building Code of New York State is not applicable, showing that the facility has been inspected and approved within the 12 months preceding the date of application for use as a child school age child care program, in accordance with the appropriate provisions of such code;
Resolution: Not Corrected
Applicants for a registration must submit to the Office: certificate of occupancy or other documentation from the local government authority having jurisdiction for determining compliance with the Fire Code and Building Code of New York State, or other applicable fire and building codes when the Fire and Building Code of New York State is not applicable, showing that the facility has been inspected and approved within the 12 months preceding the date of application for use as a child school age child care program, in accordance with the appropriate provisions of such code;
Resolution: Not Corrected
Applicants for a registration must submit to the Office: certificate of occupancy or other documentation from the local government authority having jurisdiction for determining compliance with the Fire Code and Building Code of New York State, or other applicable fire and building codes when the Fire and Building Code of New York State is not applicable, showing that the facility has been inspected and approved within the 12 months preceding the date of application for use as a child school age child care program, in accordance with the appropriate provisions of such code;
Resolution: Not Corrected
Applicants for a registration must submit to the Office: certificate of occupancy or other documentation from the local government authority having jurisdiction for determining compliance with the Fire Code and Building Code of New York State, or other applicable fire and building codes when the Fire and Building Code of New York State is not applicable, showing that the facility has been inspected and approved within the 12 months preceding the date of application for use as a child school age child care program, in accordance with the appropriate provisions of such code;
Resolution: Not Corrected
A school age child care program must cooperate with inspectors and other representatives of the Office in regard to any inspections or investigations that are conducted by the Office or its representatives.
Resolution: Corrected
The school age child care program must admit inspectors and other representatives of the Office onto the grounds and premises at any time during the hours of operation of the program. Inspectors and representatives of the Office must be given free access to the building or buildings used by the school age child care program staff and children and any records of the program.
Resolution: Corrected
The school age child care program must admit inspectors and other representatives of the Office onto the grounds and premises at any time during the hours of operation of the program. Inspectors and representatives of the Office must be given free access to the building or buildings used by the school age child care program staff and children and any records of the program.
Resolution: Corrected
The school age child care program must admit inspectors and other representatives of the Office onto the grounds and premises at any time during the hours of operation of the program. Inspectors and representatives of the Office must be given free access to the building or buildings used by the school age child care program staff and children and any records of the program.
Resolution: Corrected
A school age child care program must cooperate with inspectors and other representatives of the Office in regard to any inspections or investigations that are conducted by the Office or its representatives.
Resolution: Corrected
A school age child care program must cooperate with inspectors and other representatives of the Office in regard to any inspections or investigations that are conducted by the Office or its representatives.
Resolution: Corrected
The school age child care program must admit inspectors and other representatives of the Office onto the grounds and premises at any time during the hours of operation of the program. Inspectors and representatives of the Office must be given free access to the building or buildings used by the school age child care program staff and children and any records of the program.
Resolution: Corrected
A school age child care program must cooperate with inspectors and other representatives of the Office in regard to any inspections or investigations that are conducted by the Office or its representatives.
Resolution: Corrected
The school age child care program must admit inspectors and other representatives of the Office onto the grounds and premises at any time during the hours of operation of the program. Inspectors and representatives of the Office must be given free access to the building or buildings used by the school age child care program staff and children and any records of the program.
Resolution: Corrected
A school age child care program must cooperate with inspectors and other representatives of the Office in regard to any inspections or investigations that are conducted by the Office or its representatives.
Resolution: Corrected
Applicants for a registration must submit to the Office: certificate of occupancy or other documentation from the local government authority having jurisdiction for determining compliance with the Fire Code and Building Code of New York State, or other applicable fire and building codes when the Fire and Building Code of New York State is not applicable, showing that the facility has been inspected and approved within the 12 months preceding the date of application for use as a child school age child care program, in accordance with the appropriate provisions of such code;
Resolution: Not Corrected
Applicants for a registration must submit to the Office: certificate of occupancy or other documentation from the local government authority having jurisdiction for determining compliance with the Fire Code and Building Code of New York State, or other applicable fire and building codes when the Fire and Building Code of New York State is not applicable, showing that the facility has been inspected and approved within the 12 months preceding the date of application for use as a child school age child care program, in accordance with the appropriate provisions of such code;
Resolution: Not Corrected
Applicants for a registration must submit to the Office: certificate of occupancy or other documentation from the local government authority having jurisdiction for determining compliance with the Fire Code and Building Code of New York State, or other applicable fire and building codes when the Fire and Building Code of New York State is not applicable, showing that the facility has been inspected and approved within the 12 months preceding the date of application for use as a child school age child care program, in accordance with the appropriate provisions of such code;
Resolution: Not Corrected
Applicants for a registration must submit to the Office: certificate of occupancy or other documentation from the local government authority having jurisdiction for determining compliance with the Fire Code and Building Code of New York State, or other applicable fire and building codes when the Fire and Building Code of New York State is not applicable, showing that the facility has been inspected and approved within the 12 months preceding the date of application for use as a child school age child care program, in accordance with the appropriate provisions of such code;
Resolution: Not Corrected
Applicants for a registration must submit to the Office: certificate of occupancy or other documentation from the local government authority having jurisdiction for determining compliance with the Fire Code and Building Code of New York State, or other applicable fire and building codes when the Fire and Building Code of New York State is not applicable, showing that the facility has been inspected and approved within the 12 months preceding the date of application for use as a child school age child care program, in accordance with the appropriate provisions of such code;
Resolution: Not Corrected
Applicants for a registration must submit to the Office: certificate of occupancy or other documentation from the local government authority having jurisdiction for determining compliance with the Fire Code and Building Code of New York State, or other applicable fire and building codes when the Fire and Building Code of New York State is not applicable, showing that the facility has been inspected and approved within the 12 months preceding the date of application for use as a child school age child care program, in accordance with the appropriate provisions of such code;
Resolution: Not Corrected
Applicants for renewal of a registration must submit to the Office at least 60 days in advance of the expiration date of the registration the following: documentation from an inspector for the New York State Department of Labor or an insurance company licensed to write boiler insurance in New York State showing that all steam or hot water boilers have been inspected and approved during the current registration period in accordance with the requirements of the New York State Department of Labor. For all other fuel burning heating systems and equipment and boilers not subject to the New York State Department of Labor requirements, documentation of service by a heating contractor performed within the 12 months preceding the date of the application for renewal; and
Resolution: Corrected
The program must maintain on file at the program, available for inspection by the Office or its designees at any time, the following records in a current and accurate manner: documentation showing inspection and approval of any steam or hot water boilers performed in accordance with the requirements of the New York State Department of Labor and service performed once every 24 months during the current registration period on all other fuel burning heating systems and equipment and boilers not subject to the New York State Department of Labor requirements.
Resolution: Corrected
The program must maintain on file at the program, available for inspection by the Office or its designees at any time, the following records in a current and accurate manner: documentation showing inspection and approval of any steam or hot water boilers performed in accordance with the requirements of the New York State Department of Labor and service performed once every 24 months during the current registration period on all other fuel burning heating systems and equipment and boilers not subject to the New York State Department of Labor requirements.
Resolution: Corrected
Applicants for a registration must submit to the Office: certificate of occupancy or other documentation from the local government authority having jurisdiction for determining compliance with the Fire Code and Building Code of New York State, or other applicable fire and building codes when the Fire and Building Code of New York State is not applicable, showing that the facility has been inspected and approved within the 12 months preceding the date of application for use as a child school age child care program, in accordance with the appropriate provisions of such code;
Resolution: Not Corrected
Applicants for a registration must submit to the Office: certificate of occupancy or other documentation from the local government authority having jurisdiction for determining compliance with the Fire Code and Building Code of New York State, or other applicable fire and building codes when the Fire and Building Code of New York State is not applicable, showing that the facility has been inspected and approved within the 12 months preceding the date of application for use as a child school age child care program, in accordance with the appropriate provisions of such code;
Resolution: Not Corrected
The program must maintain on file at the program, available for inspection by the Office or its designees at any time, the following records in a current and accurate manner: documentation showing inspection and approval of any steam or hot water boilers performed in accordance with the requirements of the New York State Department of Labor and service performed once every 24 months during the current registration period on all other fuel burning heating systems and equipment and boilers not subject to the New York State Department of Labor requirements.
Resolution: Corrected
Applicants for a registration must submit to the Office: certificate of occupancy or other documentation from the local government authority having jurisdiction for determining compliance with the Fire Code and Building Code of New York State, or other applicable fire and building codes when the Fire and Building Code of New York State is not applicable, showing that the facility has been inspected and approved within the 12 months preceding the date of application for use as a child school age child care program, in accordance with the appropriate provisions of such code;
Resolution: Not Corrected
Applicants for renewal of a registration must submit to the Office at least 60 days in advance of the expiration date of the registration the following: documentation from an inspector for the New York State Department of Labor or an insurance company licensed to write boiler insurance in New York State showing that all steam or hot water boilers have been inspected and approved during the current registration period in accordance with the requirements of the New York State Department of Labor. For all other fuel burning heating systems and equipment and boilers not subject to the New York State Department of Labor requirements, documentation of service by a heating contractor performed within the 12 months preceding the date of the application for renewal; and
Resolution: Corrected
The program must maintain on file at the program, available for inspection by the Office or its designees at any time, the following records in a current and accurate manner: documentation showing inspection and approval of any steam or hot water boilers performed in accordance with the requirements of the New York State Department of Labor and service performed once every 24 months during the current registration period on all other fuel burning heating systems and equipment and boilers not subject to the New York State Department of Labor requirements.
Resolution: Corrected
The program must maintain on file at the program, available for inspection by the Office or its designees at any time, the following records in a current and accurate manner: documentation showing inspection and approval of any steam or hot water boilers performed in accordance with the requirements of the New York State Department of Labor and service performed once every 24 months during the current registration period on all other fuel burning heating systems and equipment and boilers not subject to the New York State Department of Labor requirements.
Resolution: Corrected
Applicants for renewal of a registration must submit to the Office at least 60 days in advance of the expiration date of the registration the following: documentation from an inspector for the New York State Department of Labor or an insurance company licensed to write boiler insurance in New York State showing that all steam or hot water boilers have been inspected and approved during the current registration period in accordance with the requirements of the New York State Department of Labor. For all other fuel burning heating systems and equipment and boilers not subject to the New York State Department of Labor requirements, documentation of service by a heating contractor performed within the 12 months preceding the date of the application for renewal; and
Resolution: Corrected
Applicants for renewal of a registration must submit to the Office at least 60 days in advance of the expiration date of the registration the following: documentation from an inspector for the New York State Department of Labor or an insurance company licensed to write boiler insurance in New York State showing that all steam or hot water boilers have been inspected and approved during the current registration period in accordance with the requirements of the New York State Department of Labor. For all other fuel burning heating systems and equipment and boilers not subject to the New York State Department of Labor requirements, documentation of service by a heating contractor performed within the 12 months preceding the date of the application for renewal; and
Resolution: Corrected
Applicants for a registration must submit to the Office: certificate of occupancy or other documentation from the local government authority having jurisdiction for determining compliance with the Fire Code and Building Code of New York State, or other applicable fire and building codes when the Fire and Building Code of New York State is not applicable, showing that the facility has been inspected and approved within the 12 months preceding the date of application for use as a child school age child care program, in accordance with the appropriate provisions of such code;
Resolution: Not Corrected
Applicants for renewal of a registration must submit to the Office at least 60 days in advance of the expiration date of the registration the following: documentation from an inspector for the New York State Department of Labor or an insurance company licensed to write boiler insurance in New York State showing that all steam or hot water boilers have been inspected and approved during the current registration period in accordance with the requirements of the New York State Department of Labor. For all other fuel burning heating systems and equipment and boilers not subject to the New York State Department of Labor requirements, documentation of service by a heating contractor performed within the 12 months preceding the date of the application for renewal; and
Resolution: Corrected
Get Inspection Alerts
Be the first to know when new inspections or violations are reported for CONCOURSE VILLAGE, INC.
Nearby Daycares in Bronx
Lozano, Ketty
2401 Davidson Avenue
The Playhouse Family Daycare, INC
3140 Kingsbridge Avenue
LITTLE BLOOM DAYCARE INC.
31 Mount Hope Place
DIRECTIONS FOR OUR YOUTH, INC
1368 WEBSTER AVENUE
Salcedo, Nataliz
3010 Valentine Avenue
Frequently Asked Questions
What is CONCOURSE VILLAGE, INC's safety grade?
CONCOURSE VILLAGE, INC has a safety grade of F (Poor) based on state inspection data. The composite score is 55.0 out of 100.
How many violations does CONCOURSE VILLAGE, INC have?
CONCOURSE VILLAGE, INC has 50 total violations on record, including 0 critical, 50 serious, and 0 minor.
When was CONCOURSE VILLAGE, INC last inspected?
CONCOURSE VILLAGE, INC was last inspected on January 15, 2026.